INFORMATION
2.4.2

Generator control panel

Internal fuel pump
Digital Diesel Control
Fuse 3A
Fuse 3A
Remove fuse
before maintenance
Auxiliary
External Fuel Pump
Fuse 10A
Fuse 3A
Fig. 8 Control panel.
Fig. 9 Digital Diesel Control unit
2.4.3

Remote control panel

01
05
01
Generator load indicator
02
Failure LED
03
Start button
04
Stop button
05
Display
06
Select button
07
Set button
Fig. 10 Digital Diesel remote control panel.
12
Start / Stop
Whisper Digital Diesel Operation Unit
Observe instructions in the manual
Replace fuses with same type and rating
03
02
04
06
07
2.5

Technical Information

2.5.1

AC alternator

The tri phase synchronous alternator is directly coupled,
one bearing, brushless, rotating field design, 12 wire, four
pole (1800 RPM) and regulated by an Automatic Voltage
Regulator (AVR).
The exciter stator has a residual magnetism, which
guarantees self-exciting of the generator on start-up (that
thereby generates a residual voltage of about 10%
nominal voltage).
Fig. 11 Automatic Voltage Regulator (AVR)
The AVR, powered by an auxiliary circuit on the main
stator, acts on the exciter stator indirectly controlling the
field generated by the main rotor by means of the
sequence exciter rotor - diode bridge - main rotor.
The voltage regulator controls and keeps constant the
average voltage of one phase. The voltage setting on the
AVR can be adjusted with the help of a trimmer "V"
between 100 and 140 Volts (or 200 and 280V @ nominal
voltage 230V). (See par. 5.3.1)
A frequency control progressively deactivates the machine
when the drive motor speed drops below a pre-set,
adjustable threshold preventing over-excitement at low
operating speeds and abating the load engage effects on
the engine.
The AVR works only within limits of the set frequency 60
Hz. When operating below the lower limit of 56 Hz ± 1 Hz
the AVR will stop regulating to avoid overloading the
exciter coil (This setting can be changed with trimmer
"UF"). (See par. 5.3.1)
When applying the generator set at 50 Hz the AVR is re-
adjustable as well. To operate at 50 Hz the engine RPM
and Digital Diesel Control settings must also be changed.
For the European market a dedicated manual (Art. No
50200441) is available for 50 Hz applications. Please refer
to the Mastervolt service centre for specific instructions to
convert the generating set to 50 Hz.
A further option is to readjust the stability of the regulator.
In the event of very irregular (alternating) loads it could be
necessary to change this setting with the help of trimmer
Copyright © 2008 Mastervolt / December 2008 / WHISPER 30 ULTRA / US