SPECIFICATIONS

D/A converters
1
Dynamic range
Frequency response
Crosstalk
Signal delay
Total harmonic distortion
(20 Hz–20 kHz)
1
Hum & noise
CobraNet
Analog out
Computer ports
Amp control
Unit ID
Power Requirements
Dimensions
Net weight
Operating free-air temperature range
Storage temperature range
Supplied Accessories
1. Measured using a 6 dB/octave filter @ 12.7 kHz; equivalent to a 20 kHz filter with an infinite dB/octave attenuation.
(総合仕様)
24-bit, 128-times oversampling
110 dB typical
20 Hz–20 kHz +0.5, –1.5 dB (nominal output level @ 1 kHz)
–80 dB (@ 1 kHz, between adjacent channels)
0.625 ms (CobraNet to analog output)
+4 dB output
Less than 0.05%
Full scale output
Less than 0.01%
–92 dB
PRIMARY/SECONDARY
RJ-45 x2 (16 in), transformer isolated, IEEE 802.3
connectors
Network status
LINK, CONDUCT, ERROR LEDs
indicators
Channels
CH1–16 balanced outputs
Connector
Euro-block connectors 6-way x8
150 Ω
Source impedance
10k Ω lines
For use with nominal
Output level
Nominal: +4 dB (1.23 V), Max. before clip: +18 dB (6.16 V)
TO COMPUTER
9-pin male D-sub (RS-232C)
USB
USB 1.1
RS-485
RJ-45 x1
0–F (0–15)
U.S./Canada
110–120 V, 50/60 Hz, 40 W
Other
220–240 V, 50/60 Hz, 40 W
(W x H x D)
480 x 44.65 x 385.5 mm (18 7/8" x 1 3/4" x 15 5/32"), 1U
4.8 kg (10.6 lbs)
0–40°C (32–104°F)
–20 to 60°C (–4 to 140°F)
CD-ROM (NetworkAmp Manager, PDF manual, MIDI drivers)
Power cord and retaining clamp
USB cable
3-way Euro-block connectors x16
Owner's Manual
ACU16-C