RANGE DETECTOR RANGE (default = LOW)
LOW
Low range 8m
High range 14m
HIGH
Note: OK light turns on each time PIR is activated.
PULSE
DETECTOR PULSE COUNT (default = 3)
Number of times (1-4) a detection beam needs to crossed before an alarm occurs
1-4
Note: OK light turns on each time PIR is activated.
SIGNAL
SIGNAL CHECK: Check signal strength of radio detectors and keys
SecurityGuard registers the first device received and displays the signal strength (1-9), and
beeps a corresponding number of times.
Press ON to activate Signal Check display shows "SEND DEVICE"
For a key, press PANIC; for a detector, activate the detector
Listen to beeps, view display
Press OFF to exit Signal Check
Press ON to re-activate Signal Check
--
SENS 2-23
KEY 1-23
1-9
Note: OK light indicates main detector trigger
RADJAM
RADIO JAMMING (default = OFF)
In the event of a SecurityGuard sensing a continuous (>30 secs) source of Radio Frequency
Interference (RFI), it can generate a CHIME alarm in DISARMED or HOME or HOME 2
modes, and a full alarm in ARMED modes.
ON
Enabled
Disabled
OFF
RADSUB
RADIO INTENTIONAL MESSAGE SUBSTITUTION (default = OFF)
In the event of a SecurityGuard sensing a radio message with a recognised device ID but
failing decryption, it can generate a CHIME alarm in DISARMED or HOME or HOME 2 modes,
and a full alarm in ARMED modes.
Enabled
ON
OFF
Disabled
Doc ID. SG3PROG00103_03_2014.DOC
No detectors received
Detector x received
Key x received
Signal strength