Guide Tube Unit, Soldering A7 - Nikon COOLPIX 3700 Repair Manual

Hide thumbs Also See for COOLPIX 3700:
Table of Contents

Advertisement

VAA18001-R.3622.A
Guide tube unit
① Set the guide tube and cam tube 2 at the below position.
② Attach the guide tube unit on the master frame unit with 4 screws (#194-35014).
③ Check if the barrier is completely closed.
Same level of height
Guide tube
Cam tube 2
194-35014×4
Guide tube unit
Master frame unit
Soldering
Shutter FPC
194-25014
Main FPC
Solder
Folding part of FPC
- A7 ・ E3700 -