12.7
Indication Panel
Note:
If Operation LED is blinking, there is an abnormality operation occurs.
12.8
Quiet Operation
Purpose:
- To provide quiet operation compare to normal operation by reduces outdoor unit noise.
Starting condition:
1
When quiet button is presses.
2
When quiet request ON time by weekly timer (Refer to control panel.)
When any of above mentioned condition is achieved, this control is activated.
During quiet operation, operating frequency and outdoor FM rpm will be reduced. It will result in capacity loss.
Cancellation condition:
1
Cancel by press quiet button
2
Stop by OFF/ON button
3
When quiet request OFF time by weekly timer
When any of above mentioned condition is achieved, this control is cancelled.
LED
Color
Light ON
Light OFF
35
Operation
Green
Operation ON
Operation OFF