2. ABSOLUTE MAXIMUM RATINGS

2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Storage Temperature
Operating Ambient Temperature
Shock (Non-Operating)
Vibration (Non-Operating)
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Note (2) The maximum operating temperature is based on the test condition that the surface temperature of
display area is less than or equal to 80 ºC with LCD module alone in a temperature controlled chamber.
Thermal management should be considered in your product design to prevent the surface temperature
of display area from being over 80 ºC. The range of operating temperature may degrade in case of
improper thermal management in your product design.
Note (3) 2 ms, half sine wave, 1 time for ± X, ± Y, ± Z.
Note (4) 10 ~ 300 Hz, 10 min, 1 time each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough so that
the module would not be twisted or bent by the fixture.
-30
Panel Specification
Item
40 ºC).
Relative Humidity (% RH)
100
90
80
70
60
50
Operation Range
40
30
20
Storage Range
10
0
-20
-10
0
Temperature (ºC)
Symbol
Min.
T
(-20)
ST
T
(-10)
OP
S
-
NOP
V
-
NOP
10
20
30
Value
Max.
(+70)
(+60)
(220)
(1.5)
40
50
60
Unit
Note
ºC
(1)
ºC
(1), (2)
G
(3), (5)
G
(4), (5)
70
80