Comfort and energy saving functions
Selecting energy saving function "Holiday program"
If the heating program "Only
DHW" is selected for all heating cir-
cuits, frost protection monitoring is
only enabled for the boiler and DHW
cylinder.
■ DHW heating:
DHW heating is switched OFF; frost
protection monitoring for the DHW cyl-
inder is active.
The holiday program starts at 00:00 h the
day following your departure and ends at
00:00 h on the day of your return. This
means the selected time program is
active on the days of departure and
return (see page 23).
Extended menu:
1.
2. "Heating"
28
3. "Holiday program"
Heating circuit 1
Heating program
Heating time program
Holiday program
Heating curve
Continue with
4. Set the required departure and return
dates.
Holiday program
Leaving date:
Date
Return date:
Date
Select with
Display in the extended menu
In the extended menu, you can scan the
selected holiday program under "Infor-
mation" (see chapter "Scanning infor-
mation", "Heating circuit ..." group).
Terminating or deleting a holiday pro-
gram
Extended menu
1.
2. "Heating"
3. "Holiday program"
4. "Delete program"
(cont.)
HC1
Ù
Ú
ê
OK
HC1
Tu 21/12/2010
We 22/12/2010
(