Checking 30", 36", Or 48" Rh Oven Bake Operation - Viking VGSC530 Service Manual

30, 36, & 48 inch self-clean gas ranges
Hide thumbs Also See for VGSC530:
Table of Contents

Advertisement

Troubleshooting
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Checking 30", 36", or 48" RH Oven Bake Operation

Disconnect power to the range
Access control panel and wiring
Connect power
120 VAC present on oven control L1 (P20) to L2 (P19)?
120 VAC present on spark module A to N?
Yes
RTD open or shorted?
(See fault codes on page 12).
No
Selector switch or thermostat open?
(See chart on page 22).
No
Turn selector switch to Bake
and thermostat to 350°.
120 VAC present on bake relay
(P12) Violet to Black?
Yes
Turn selector switch to Bake
and thermostat to 350°.
120 VAC present on DSI
module H1 to N?
Yes
10.75 VAC present on DSI
module SC to S1?
Yes
10.75 VAC present on DSI
module SC to S1 while
arcing, yet no gas present
to bake burner? (Gas supply
valve in open position)
No
Repair or replace defective wiring.
18
Yes
Replace RTD.
Replace selector
Yes
switch or thermostat.
No
Replace oven control board.
Repair or replace
No
defective wiring.
No
Replace DSI module.
Disconnect power to range.
Check bake solenoid resistance.
Yes
210  present S1 brown to SC black\white?
Replace bake solenoid
valve.
Open high
No
limit switch?
No
Repair or replace
defective wiring.
No
©2010 Viking Preferred Service
Replace high
Yes
limit switch.