Cleaning The Unit From The Outside; Suction Filter Hc 920; Cleaning The High-Pressure Filter - WAGNER HC 920 Operating Manual

Airless high-pressure spraying unit
Table of Contents

Advertisement

Available languages

Available languages

Interruption of work
9. Move the hydraulic ball valve on the material feed pump to
its horzontal position (closed).
10. Turn off the gasoline engine or electric motor.
8.1

Cleaning the unit from the outside

Gasoline units — Switch off the gasoline engine
and let it cool down.
Electric units — Unplug the mains plug from the
Danger
socket.
Danger of short-circuits through penetrating
water.
Never spray down the unit with high-pressure or
Danger
high-pressure steam cleaners.
Wipe the unit off with a cloth soaked in a suitable cleaning agent.
GB
8.2
Suction filter on HC 920
i
A clean suction filter always guarantees maximum
feed quantity, constant spraying pressure and
problem-free functioning of the unit.
– Screw off the filter (fig. 15) from suction pipe.
– Clean or replace the filter.
Carry out cleaning with a hard brush and an appropriate
cleaning agent.
8.3

Cleaning the high-pressure filter

Clean the filter cartridge regularly.
A soiled or clogged high-pressure filter can cause a poor spray
pattern or a clogged tip.
Disassembly
1. Move the hydraulic ball valve on the material feed pump to
its horzontal position (closed).
Flow of hydraulic oil to hydraulic motor of material feed
pump is interrupted.
2. Turn the relief valve handle (3) fully counterclockwise (k
Circulation).
3. Turn off the gasoline engine or electric motor.
4. Unscrew the housing cover (fig. 16, item 1).
5. Pull filter cartridge (3) out of housing (8).
6. Clean the pressure spring (2) and filter cartridge (3) with
an appropriate cleaning agent, clean the inside of the
housing (8) and housing cover (1).
7. Check ball in the filter cartridge (3) for wear and replace
filter cartridge, if necessary.
8. If ball in filter cartridge (3) is thoroughly worn, aremove
O-ring (6) and valve seat (7). Replace worn valve seat, if
necessary.
9. Always replace O-ring (6) after removal.
10. Pull off pressure spring (2) from housing cover (1).
Measure length of pressure spring, and replace if shorter
than 19 mm.
44
Cleaning the unit (shutting down)
HC 920 • HC 940 • HC 960

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hc 940Hc 960Hc 940-sspHc 960-ssp

Table of Contents