Unit Start Up - Lennox ELITE EL195UHE Installation Instructions Manual

Upflow / horizontal air discharge
Hide thumbs Also See for ELITE EL195UHE:
Table of Contents

Advertisement

INTEGRATED CONTROL
(Automatic Hot Surface Ignition System)
RED LED
RECALL BUTTON
FIGURE 58
TABLE 10
1/4" QUICK CONNECT TERMINALS
120HUM
Humidifier 120VAC
LINE
120VAC
XFMR
Transformer 120VAC
CIRC
Indoor blower 120VAC
EAC
Indoor air quality accessary 120VAC
NEUTRALS
Common 120VAC
HUM24
Humidifier 24VAC
3/16" QUICK CONNECT TERMINALS
COOL
Cooling tap 24VAC
HEAT
Heating tap 24VAC
FAN
Continuous blower 24 VAC
PARK (no power)
Park terminal for speed taps
FS
Flame sense
24 COM
Common 24VAC
BLOWER OFF DELAY
Page 42
Unit Start-Up
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING
Do not use this furnace if any part has been under­
water. A flood-damaged furnace is extremely dan­
gerous. Attempts to use the furnace can result in fire
or explosion. Immediately call a qualified service
technician to inspect the furnace and to replace all
gas controls, control system parts, and electrical
parts that have been wet or to replace the furnace, if
deemed necessary.
WARNING
Danger of explosion. Can cause injury
or product or property damage. Should
the gas supply fail to shut off or if
overheating occurs, shut off the gas
valve to the furnace before shutting off
the electrical supply.
CAUTION
Before attempting to perform any service or mainte­
nance, turn the electrical power to unit OFF at dis­
connect switch.
BEFORE LIGHTING the unit, smell all around the furnace
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
The gas valve on the EL195UHE is equipped with a gas
control switch (lever). Use only your hand to move switch.
Never use tools. If the the switch will not move by hand, do
not try to repair it. Force or attempted repair may result in a
fire or explosion.
Placing the furnace into operation:
EL195UHE units are equipped with an automatic hot sur­
face ignition system. Do not attempt to manually light burn­
ers on this furnace. Each time the thermostat calls for heat,
the burners will automatically light. The ignitor does not get
hot when there is no call for heat on these units.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents