Lennox ELITE EL195UHE Installation Instructions Manual page 30

Upflow / horizontal air discharge
Hide thumbs Also See for ELITE EL195UHE:
Table of Contents

Advertisement

NOTE − FIELD−PROVIDED
REDUCER MAY BE
REQUIRED TO ADAPT
LARGER VENT PIPE SIZE
TO TERMINATION
D
B
C1
A
APPPLICATION
* WALL
SUPPORT
E
A
C1
APPLICATION
ALTERNATE TERMINATIONS (TEE & FORTY−FIVE DEGREE ELBOWS ONLY)
B
D
1
C
2
A
D
1
E
B
12"
C
2
A
FIELD FABRICATED WALL TERMINATION
Intake
C2
Elbow
A
STRAIGHT
D
E
B
C2
EXTENDED
B
Exhaust
D
C
Intake
Elbow
A
Front View of
Intake and Exhaust
Intake
Exhaust
1
The exhaust termination tee should be connected to the 2" or 3" PVC flue pipe as shown in the illustration.
Do not use an accelerator in applications that include an exhaust termination tee.
The accelerator is not required.
2
As required. Flue gas may be acidic and may adversely affect some building materials. If a side wall vent
termination is used and flue gases will impinge on the building materials, a corrosion−resistant shield
(24 inches square) should be used to protect the wall surface. If optional tee is used, the protective shield
is recommended. The shield should be constructed using wood, sheet metal or other suitable material.
All seams, joints, cracks, etc. in affected area, should be sealed using an appropriate sealant.
3
Exhaust pipe 45° elbow can be rotated to the side away from the combustion air inlet to direct exhaust
away from adjacent property. The exhaust must never be directed toward the combustion air inlet.
A− Minimum clearance
above grade or average
snow accumulation
D
B− Maximum horizontal
separation between
intake and exhaust
C1 -Minimum from end of
B
exhaust to inlet of intake
C2 -Minimum from end of
exhaust to inlet of intake
D− Maximum exhaust
pipe length
E− Maximum wall support
distance from top of each
pipe (intake/exhaust)
D
See venting table 5 for maximum venting lengths
with this arrangement.
* Use wall support every 24" (610 mm). Use two
B
wall supports if extension is greater than
24" (610 mm) but less than 48" (1219 mm).
NOTE − One wall support must be within 6" (152 mm)
A
from top of each pipe (intake and exhaust) to prevent
movement in any direction.
A− Clearance above
grade or average snow
accumulation
B− Horizontal
3
separation between
intake and exhaust
C− Minimum from
end of exhaust to
inlet of intake
D− Exhaust pipe length
E− Wall support distance
from top of each pipe
(intake/exhaust)
FIGURE 41
Page 30
2" (51mm)
3" (76mm)
Vent Pipe
Vent Pipe
12" (305 mm)
12" (305 mm)
6" (152 mm)
6" (152 mm)
8" (203 mm)
8" (203 mm)
6" (152 mm)
6" (152 mm)
12" (305 mm)
20" (508 mm)
6" (152 mm)
6" (152 mm)
2" (51MM)
3" (76MM)
Vent Pipe
Vent Pipe
12" (305 mm) Min. 12" (305 mm) Min.
6" (152 mm) Min.
6" (152 mm) Min.
24" (610 mm) Max.
24" (610 mm) Max.
9" (227 mm) Min.
9" (227 mm) Min.
12" (305 mm) Min.
12" (305 mm) Min.
16" (405 mm) Max.
20" (508 mm) Max.
6" (152 mm) Max.
6" (152 mm) Max.