H. STEAM INFORMATION
It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas
plumbing installation is adequate and conforms with local and state regulations or codes.
IMPORTANT: Failure to comply with the requirements stipulated in this manual can result in
component failure, which will VOID THE WARRANTY.
NOTE: The CG145-55 is manufactured with a pneumatic (piston) damper system, which requires an
external supply of clean, dry, and regulated air 80 PSI +/- 10 PSI (5.51 bars +/- 0.68 bars).
Refer to Steam Damper Air System Connections , Section H, item 4.
1. Steam Coil PH Level
The normal PH level for copper type steam coils must be maintained between a value of 8.5 to 9.5. For
steel type steam coils the PH level must be maintained between a value of 9.5 to 10.5. These limits are set
to limit the acid attack of the steam coils.
IMPORTANT: Coil failure due to improper PH level will VOID THE WARRANTY.
2. Steam Requirements - High Pressure
Inlet -------- 1-1/2" supply line connection -- qty. one (1) at top manifold.
Return ----- 1-1/2" return line connection --- qty. one (1) at bottom manifold.
M
AXIMUM
M
INIMUM
H
I
(N
EAT
NPUT
ORMAL
C
(A
ONSUMPTION
PPROXIMATE
Shaded areas are stated in metric equivalents
3. Installation Instructions
To insure an adequate supply of steam is provided, be sure that the steam lines and steam return lines are
sized and laid out as stipulated in this manual. Inadequate steam lines and steam return lines or improper
steam plumbing will result in poor performance and can cause component failure. Clean, dry steam must
be provided to the dryer.
IMPORTANT: Steam coil failure due to water hammer by wet steam will VOID THE WARRANTY.
O
S
PERATING
L
)
OAD
)
P
TEAM
RESSURE
125 psig
100 psig
16 Bhp
520 lbs/hr
29
862 kPa
689 kPa
235 kg/hr