Configure Chap Authentication On The Host Server Using Suse Linux Enterprise Server Gui; Step 7: Connect To The Target Storage Array From The Host Server; Connect To The Target Storage Array From The Host Server Using Windows Server Gui - Dell PowerVault MD3860i Series Deployment Manual

Storage arrays
Hide thumbs Also See for PowerVault MD3860i Series:
Table of Contents

Advertisement

03.com.redhat01.78b1b8cad821 discovery.sendtargets.auth.password =
password_1
discovery.sendtargets.auth.username = iqn.1984-
123456discovery.sendtargets.auth.password_in =
Configure CHAP Authentication On The Host Server Using SUSE Linux
Enterprise Server GUI
1.
Click Desktop→ YaST→ iSCSI Initiator.
2.
Click Service Start, then select When Booting.
3.
Select Discovered Targets, then select Discovery.
4.
Enter the IP address of the port.
5.
Click Next.
6.
Select any target that is not logged in and click Log in.
7.
Select one of the following:
If you are not using CHAP authentication, select No Authentication. Go to step 8.
or
If you are using CHAP authentication, enter the CHAP user name and password. To enable Mutual
CHAP, select and enter the Mutual CHAP user name and password.
8.
Repeat step 7 for each target until at least one connection is logged in for each controller.
9.
Go to Connected Targets.
10. Verify that the targets are connected and the status is true.
Step 7: Connect To The Target Storage Array From The
Host Server
Connect To The Target Storage Array From the Host Server Using Windows
Server GUI
1.
Click Start → All Programs → Administrative Tools → iSCI Initiator.
2.
Click the Targets tab.
If previous target discovery was successful, the iqn of the storage array should be displayed under
Targets.
3.
Click Log On.
4.
Select Automatically restore this connection when the system boots.
5.
Select Enable multi-path.
6.
Click Advanced and configure the following settings under the General tab:
Local Adapter—Must be set to Microsoft iSCSI Initiator.
Source IP—The source IP address of the host server you want to connect from.
Target Portal—Select the iSCSI port on the storage array controller that you want to connect to.
Data Digest and Header Digest—Optionally, you can specify that a digest of data or header
information be compiled during transmission to assist in troubleshooting.
CHAP logon information—If CHAP authentication is required, select this option and enter the
Target secret.
Perform mutual authentication—If mutual CHAP authentication is configured, select this option.
05.com.dell:powervault.
test1234567890