9. A/D DATA CHECK
This menu is used to display the A/D conversion
value of the microprocessor which detects panel keys
of this unit and protection functions by using the sub-
menu.
When K0/K1 menu is selected, keys become non-
operable due to detection of the values of all keys.
In order to turn on the power again, disconnect the
power cable of this unit from the AC outlet once and
then reconnect it again.
*
The figures in the diagram are given as reference
only.
PS1/PS2
PSx:
Power supply voltage protection detection
PS1
Voltage detects: AC_BL, AC_12, AC_5, ±12 and
+5V
Normal value:
38 to 128
(Reference voltage: 3.3 V=255)
PS2
Voltage detects: -5 and +5I
Normal value:
31 to 125
(Reference voltage: 3.3 V=255)
*
If PS1 and PS2 are out of the normal value
range, the protection function works to turn
off the power.
9. A/D DATA CHECK
本機パネルキー、プロテクションなどを検出してい
るマイコンの A/D 変換値を、サブメニューで表示し
ます。
K0/K1 のメニューにすると、全キーの値を検出するた
めキー操作はできなくなります。
再度電源を入れる場合、一度本機の電源コードを AC
電源コンセントから抜いて接続し直してください。
※ 図中の数値は参考例です。
PS1/PS2
PSx:
電源電圧プロテクションの検出
PS1
検出電圧: AC_BL、AC_12、AC_5、±12、+5V
正常値:
PS2
検出電圧: -5V、+5I
正常値:
※ PS1 および PS2 は正常値を外れるとプロテク
ションが働き、電源が切れます。
P S 1 : 0 8 9
2 : 0 7 8
RX-V565/HTR-6250/AX-V565
38 ∼ 128
(基準電圧:3.3 V = 255)
31 ∼ 125
(基準電圧:3.3 V = 255)
51