Q1300/Q1800 - Self Contained - 3 Phase With Terminal Board - Manitowoc QR0320A Service Manual

Q series
Table of Contents

Advertisement

Section 6

Q1300/Q1800 - SELF CONTAINED - 3 PHASE WITH TERMINAL BOARD

SEE SERIAL PLATE FOR VOLTAGE
L3
L2
L1
TB35
HIGH PRES
CUTOUT
ICE THICKNESS PROBE
WATER LEVEL PROBE
TB35
(42)
TB35
L3
L2
L1
T2
COMPRESSOR
T3 T1
Part No. 80-1100-3
CAUTION: DISCONNECT POWER BEFORE WORKING
ON ELECTRICAL CIRCUITRY.
DIAGRAM SHOWN DURING FREEZE CYCLE
TB32
(55)
AUCS DISPENSE TIME
(62)
(63)
(64)
BIN SWITCH
(65)
(66)
(95)
NOTE: WIRE (96) IS NOT USED ON 50HZ
TB33
(52)
(85)
FAN CYCLE CONTROL
(20)
(61)
(60)
2
4
1
3
5
TRANS.
FUSE (7A)
1C
1F
CLEAN LIGHT
LOW D.C.
1G
VOLTAGE
WATER LEVEL LIGHT
PLUG
BIN SWITCH LIGHT
HARVEST LIGHT/
SAFETY LIMIT CODE LIGHT
TOGGLE SWITCH
(68)
ICE
(67)
(69)
OFF
(66)
CLEAN
(62)
CRANKCASE HEATER
(96)
TB34
(86)
(53)
RUN CAPACITOR**
Electrical System
WATER
(21)
VALVE
RH HARVEST
SOLENOID
(88)
(77)
(80)
LH HARVEST
SOLENOID
(76)
(81)
DUMP
SOLENOID
(57)
TB31
(98)
WATER
PUMP
(58)
TB37
(59)
TERMINATES AT
PIN CONNECTION
(73)
CONTACTOR
COIL
(56)
VIEW FOR WIRING
INTERNAL WORKING
66
VIEW
62
(94)
FAN MOTOR
(AIR COOLED ONLY)
(22)
(87)
N - 50HZ
ONLY
(75)
TB30
TB30
(99)
TB30
(74)
TB30
TB30
68
67
69
TB30
TB30
TB30
SV1653
6-27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents