Air Flow Monitor; Pump Fault Or Low Pressure; Sensor Fault; Pump Protection - Potterton Performa 28 User Operating Instructions Manual

Gas fired wall mounted combination boiler
Hide thumbs Also See for Performa 28:
Table of Contents

Advertisement

Pump/Low
Pressure Neon
Air Flow
Monitor Neon
30° 40° 50° 60° 70° 80°
Fig. 12
Reset
Fig. 13
Reset
Fig. 14

Sensor Fault

Neons
3.0 Operating the Boiler
3.5

Air Flow Monitor

1. The boiler is fitted with an air pressure sensing
device. This monitors the flue system.
2. If the neon illuminates (
the flue or flue terminal is blocked or obstructed in
some way, or that there is an internal fault. If there
is no external blockage of the flue terminal that
can be easily removed contact your Service
Engineer (Fig. 12).
3.6

Pump Fault or Low Pressure

1. The neon (
) will illuminate if the circulating
pump is faulty or the system pressure drops
below the minimum requirement (Fig. 12).
2. Check the pressure gauge as descibed in
Section 3.9. If the pressure is in the normal range,
a pump fault is indicated. Contact your Service
Engineer to determine the nature of the fault.
3.7
Sensor Fault
1. When the (
) or (
) neon is illuminated a
fault on the hot water or central heating
temperature sensor is indicated (Fig. 12). Contact
your Service Engineer.
3.8

Pump Protection

1. With the selector switch in either Position (i) or
Position (ii) (Figs. 13 & 14) the pump will
automatically operate for 1 minute in every 24
hours to prevent sticking.
) it indicates that
7