Troubleshooting
Fault codes
(cont.)
Dis-
Const.
played
fault
code
EE
X
EF
X
F0
X
F1
X
102
Weath.-
System char-
comp.
acteristics
X
Burner in a fault
state
X
Burner in a fault
state
X
Burner blocked Internal fault
X
Burner in a fault
state
Cause
Measures
Flame signal
Check the ionisa-
is not present
tion electrode and
or too weak at
connecting cable,
burner start
measure the ioni-
sation current,
check the gas sup-
ply (gas pressure
and gas flow lim-
iter), check the gas
train, ignition, igni-
tion module, igni-
tion electrodes and
the condensate
drain.
Press reset button
R.
The flame is
Check the gas sup-
lost immedi-
ply (gas pressure
ately after it
and gas flow lim-
has built (dur-
iter), check the flue
ing the safety
gas/ventilation air
time).
system for flue gas
recirculation,
check the ionisa-
tion electrode
(replace if
required).
Press reset button
R.
Replace the control
unit.
Flue gas tem-
Check the heating
perature lim-
system fill level.
iter has
Vent the system.
responded.
Press reset button
R after the flue sys-
tem has cooled
down.