Installation; Quick Instructions - Teleste EASI User Manual

Ipe mpeg-2 encoder & ipd mpeg2 decoder
Table of Contents

Advertisement

Installation

2

Quick Instructions

Install the fi eld hardened stand-alone IPE3/IPD3 device
(1U high, 19" wide) to the installation cabinet. A 12 V supply
voltage is provided by a CPS24x mains adapter.
1
Install the rack mount IPE1/IPD1 device into a DVX002-
installation frame equipped with a DVP power supply.
Switch on the system power and see that the "M", "C" and
"V" -indicators on the front panel of the device are lit.
2
The "M" (=module) should lit green to show that hardware is
operating properly.
Connect all needed audio/data signals to their respective
3
connectors on the device's front panel.
Connect either a CVBS video signal to the BNC connector or
4
a S-VIDEO signal to the mini-DIN connector of the device.
Connect the Ethernet 100Base network to port "10/100Base-
Tx/Fx" in the rear panel.
5
Note! You can create a local WebUI connection by this
connector using an Ethernet cable (e.g. OPUS1CCC0050X
cross-connection cable when CAT-5 interface).
Create management connection to the device either by over an
Ethernet network or by a Mgmt port and then set all necessary
settings in the device.
6
Default network addresses for the devices are the following:
IPE: 10.9.96.10 (IP address)
IPD: 10.9.96.20 (IP address)
IPE/IPD: 255.255.255.0 (Netmask address)
Make sure that the device is not indicating any alarms or
warnings. The "M", "C" and "V" -indicators on the front panel
7
should now lit green. If the "M" indicator is red, the device in
question has a module error and is giving an alarm.
Picture 1.
CPS24x series power supply with connector.
IPE & IPD series user manual rev002