2. SPECIFICATION

Model
Power supply
Function
Capacity
Capacity Dehumidification
Capacities
Air flow
Power outlet
Running current
Power input
Auxiliary heater
Electrical
Data
Power factor
Starting current
Compressor motor current
Fan motor current
Coeffient of performance (C.O.P)
Model
Compressor
Output
Winding resistance (at 20 C)
Indoor
Model
Fan motor
Winding resistance (at 20 C)
Outdoor
Model
Fan motor
Winding resistance (at 20 C)
Width
Dimensions
Height
Indoor unit
Depth
Width
Dimensions
Height
Outdoor unit
Depth
Weight
Indoor unit
Weight
Outdoor unit
Liquid pipe
Refrigerant
Gas pipe
piping
Connection method
Air direction
Air direction
Indoor unit
Sound level
(HI) Outdoor unit
Indoor unit
Fan speed
(HI) Outdoor unit
Indoor unit
Fan speed
regulator
Outdoor unit
Refrigerant filling capcity (R-22)
Special remarks
Thermitstor RT1(at 25 C)
NOTE:Test conditions:
Cooling:Indoor :DB 27
Cooling:Outdoor :DB 35
o
o
o
o
o
o
C/WB 19
C
o
o
C/WB 24
C
TGI-07H
AC 220V
Cooling
Units
2.2
KW
l/h
0.9
340
A
10
A
3.50
750
W
A(KW)
%
97
A
15
A
6.5
A
0.31
2.9
SG433
W
800
3.73
YYW11-2-311
280
YDK27-6H-2
296
mm
805
mm
265
mm
148
mm
750
mm
530
mm
270
kg
7.5
kg
36.0
6.35 (1/4”)
mm (”)
9.52 (3/8”)
mm (”)
Flared
6
dB
32/39
dB
48
rpm
1850/1700/1600
dB
750
Speed
Speed
kg
0.70
k
5.286
NOTE:Test conditions:
Heating:Indoor :DB 20
Heating:Outdoor :DB 7
5
TGI-09H
AC 220V
~ 50Hz
Heating
Cooling
2.5
2.30
1.0
1.2
340
450
10
10
3.30
4.3
950
710
97
15
6.5
0.5
2.8
SG633
800
3.73
YYW11-2-311
280
YDK27-6H-2
296
805
265
148
750
530
270
7.5
37.0
6.35 (1/4”)
9.52 (3/8”)
Flared
34/40
48
1850/1700/1600
750
3
1
5.286
o
C/WB 15
o
C/WB 6
~ 50Hz
Heating
3.0
1.2
450
10
4.3
950
6
3
1
0.84
o
C
o
C