9. CONTROL MODE

3. Automatic mode.

3.1 When the remote controller is set to start the unit in the automatic mode , the
airconditioner judges according to the differences between the room
temperature and temperature setting and selects a run mode.
Indoor temperature ≥ temperature setting , the unit runs in the cooling mode.
Indoor temperature < temperature setting , the unit runs in the heating mode.
3.2 The run mode is determined when the unit gets started at the first time. Once
the mode is selected , it will not change within 30 min'.
3.3 If the difference between the room temperature and temperature setting is
above 3ºC , the run mode can be changed immediately.
3.4 When the unit is turned off and restarted with the remote controller , these
conditions remain valid.
3.5 When powered off and powered on again , the airconditioner will reselect run
mode.
3.6 The indoor and outdoor and compressor control in the automatic mode are
same as that in the heating and cooling mode.
3.7 After being set to the cooling only type in EE, the heating mode doesn't work.

4. Cooling mode

4.1 In the cooling mode , the temperature setting is selected by using the remote
controller from 16 - 30ºC
4.2 When powered on for the first time , the compressor can be started
immediately.After running off , the compressor must not be restarted until at
least 3 minutes later.
4.3 After turning on , the compressor must run for at least 5 minutes.

Indoor fan speed.

Fan speed
TGI 07H-09H
Turbo
High
Low
Mute
Ultra low
TGI 12H
1,950
1,950
1,850
1,850
1,700
1,700
1,600
1,600
1,500
1,500
TGI 18H
1,300
1,250
1,050
900
850