2.9

Technical data

Technical characteristics
1)
Power
Usable power
Minimum usable power
Regulatory field
Nominal power
Minimum nominal power
Gas data
Inlet pressure
G.P.L. (Butane/Propane)
Consumption*
G.P.L. (Butane/Propane)
Gas connection
Water data
Maximum admissible pressure
Minimum working pressure
Startup flow
Flow corresponding to a temperature rise of 25 °C
Water connection
Smoke circuit
3)
Combustion gas flow
Temperature of gases at extractor grill
Using maximum possible drive compression (4 m)
Using minimum drive compression (0,37 m)
Flue socket dia.
Electrical circuit
Tension (50 HZ)
Maximum power limit
Type of protection
General Data
Weight (excluding packaging)
Height
Width
Depth
Table 5
1) GPL: Butane 45.65 MJ/kg (12.7 kWh/kg) – Propane 46.34 MJ/kg (12.9 kWh/kg)
2) In order to account for the dilation effect of water, it should not exceed this value.
3) For nominal calorific power
2)
Appliance specifications | 7
Symbols
Units
Pn
kW
Pmin
kW
Qn
kW
Qmin
kW
G30/G31
mbar
G30/G31
kg/h
pw
bar
pwmin
bar
l/min
l/min
kg/h
°C
°C
mm
V
W
kg
mm
mm
mm
WT11
19,3
7
7 - 19,3
21,8
9
28-30/37
1,9
3/4"
12
0,3
3,2
11
3/4"
50
170
220
Ø60/100
230
65
IPX4D
20
670
340
220
6 720 607 800 (2016/02)