Replacing The Flexiblelom; Replacing The P721M Controller - HP StoreVirtual 4630 Maintenance Manual

Table of Contents

Advertisement

2.
Insert two replacement drives.
3.
Reinstall the storage blade by following the quick restore instructions, see
system recovery of the HP 4630 storage system" (page
CAUTION:
log in to TUI using iLO and select Initiate OS Recovery. The OS configuration is restored from a
backup and the storage blade is rebooted. After the reboot, the storage blade is discovered as
part of the management group.

Replacing the FlexibleLOM

NOTE:
For detailed instructions, see
maintenance and service guide.
1.
Verify component failure by checking the following:
The storage system cannot be discovered using the CMC.
The link status shows it is off.
2.
Power down the storage blade.
3.
Remove the storage blade from the blade enclosure.
4.
Remove the top cover from the storage blade.
5.
Disconnect the capacitor module cable and remove the P721m controller.
6.
Remove the FlexibleLOM module.
7.
Install the replacement FlexibleLOM module.
8.
Reinstall the P721m controller and reconnect the capacitor module cable.
9.
Reinstall the top cover on the storage blade.
10. Reinstall the storage blade in the blade enclosure in the same bay.
1 1. Power on the storage blade.
12. After the FlexLOM is replaced, generate a new license key and install it on the storage system.
13. If networking was configured with DHCP, you must update the DHCP reservations and assign
the same IP address to the replacement FlexLOM network port.

Replacing the P721m controller

Figure 6 (page 25)
24
Removing and replacing the HP 4630 system components
After performing field recovery, do not reconfigure RAID using the CMC. Instead,
shows the P721m controller.
15).
Table 4 (page 20)
for the applicable server blade
"Performing field