Jenn-Air Jds8850cdb Installation Instructions Manual page 10

30" (76.2 cm) slide-in dual fuel ranges
Hide thumbs Also See for Jds8850cdb:
Table of Contents

Advertisement

Available languages

Available languages

1. Feed the power supply cord through the opening in the cord/
conduit plate on bottom of range. Allow enough slack to easily
attach the wiring to the terminal block.
A
C
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires
2. Use Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-link
screw. The ground wire must be attached first.
3. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
A
B
C
A. 10–32 hex nut
B. Ground-link screw
C. Line 1 (black)
4. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges. For a 3-wire power supply cord replacement,
service kit part number 74011285 must be used.
6. Replace terminal block access cover.
10
B
D
F
E
D
D. Green ground wire
E. Neutral (center) wire
F. Line 2 (red)
3-wire connection: Power Supply Cord (optional)
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the opening in the cord/
conduit plate on bottom of range. Allow enough slack to easily
attach the wiring to the terminal block.
A
C
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires
E. Metal ground strap
2. Use ³⁄₈" nut driver to connect the neutral (white) wire and
copper ground strap provided to the center terminal block
post with one of the 10-32 hex nuts. The opposite end of the
copper ground strap should be secured to the oven back with
the green ground link-screw.
A
B
C
A. 10–32 hex nut
B. Line 1 (black)
C. Ground-link screw
3. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
4. Securely tighten hex nuts.
5. Replace terminal block access cover.
E
B
D
E
D
D. Neutral (white) wire
E. Line 2 (red)

Advertisement