To display flat color fields scroll to item 1 "IPT_RGB"
under Device 5 TEST_PAT with the [1] button.
By default the data value will be 7 which displays an all white
screen. Press the [6] button to change data values and
display the individual color fields.
Data Value
7= White
6= Yellow
5= Magenta
4= Red
3= Cyan
2= Green
1= Blue
0= Black
*Alternatively Items PAT_ENB & PAT_RGB can be used. These
patterns do not have White Balance correction enabled.
To display individual patterns scroll to item 4 "MODE"
under Device 5 TEST_PAT with the [1] button.
To display test patterns press the [3] button on the remote:
Data Value
0= Plain (white)
1= Stripe
2= Checker (small)
3= Lattice
4= Cross-hatch
5=Cross- point
6= Ramp
7= Stair Step
8= Checker (large)
9= Diagonal
10= Window
**Note if IPT_ENB is not returned to a value of "0" the
test patterns will remain on screen when power is
cycled. In this state the service OSD is not
accessible. To clear the test patterns cycle AC power
OFF/ON.