Data Call Setup From A Voice Terminal; Computer Dialing; Data Hot Line; Table 7-1. Data Feature Vs Communications Systems - AT&T DEFINITY 2500 series Network Manual

Network and data connectivity
Hide thumbs Also See for DEFINITY 2500 series:
Table of Contents

Advertisement

7-10
DATA CONNECTIVITY — AN OVERVIEW
_ ___________________________________________________________________________________________________________________________
_ ___________________________________________________________________________________________________________________________
_ ___________________________________________________________________________________________________________________________
Data Services Features
Data Call Setup From a Voice Set
1-Button Transfer with Preindication
Manual Transfer
Terminal Dialing
Numeric Dialing
Default Dialing
Mnemonic Dialing

Computer Dialing

Data Hot Line

Data Privacy/Data Protection
Data Restriction/Data Protection
Data Only Off-Premises Extension
computer port. In the administration of mnemonic dialing, one table that cross-references mnemonic
names to telephone numbers is created and maintained on the switch.

Data Call Setup From a Voice Terminal

This features lets users dial the data endpoint from a voice terminal with an associated data module. This
feature must be used in lieu of Terminal Dialing to establish connections for synchronous (for example,
IBM 3274) terminals that do not have an RS-366 automatic calling unit (ACU) interface.
Computer Dialing
This feature makes it possible for a host computer to automatically dial a data endpoint. Hosts can
originate data calls when their ports are equiped with data modules or modems that have an ACU. The
hosts must also have software that manages call initiation and termination.
Data Hot Line
With this feature, the switch automatically dials a default number when the user presses the BREAK key at
the terminal or the Originate/Disconnect bottom on the data module. This feature is an administrable
option.

Table 7-1. Data Feature vs Communications Systems

System 75
R1V1
R1V2
R1V3
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Generic 1
R2V1
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
System 85
R2V2
R2V3
R2V4
Generic 2
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Advertisement

Table of Contents
loading

Table of Contents