42HQE009/012/018/022-38YE009/012/018/022

Indoor unit installation

Dimensions and Minimum clearances (mm)
100
min.
Model
A mm
B mm
C mm
1. Pass the piping through the hole in the wall.
2. Put the upper claw at the back of the indoor unit on the upper
hook of the installation plate, move the indoor unit from side
to side to see that it is securely hooked.
3. Piping can easily be made by lifting the indoor unit
A
90 min.
2000
min.
42HQE009
42HQE012
750
250
188
200
min.
42HQE018
815
906
280
286
195
235
with a cushioning material between the indoor unit
and the wall.
Get it out after finish piping.
4. Push the lower part of the indoor unit up on the wall, then move
the indoor unit from side to side, up and down to check if it is
hooked securely.
E N G L I S H
C
Obstacle
42HQE022
1080
330
222
Upper hooker
Low hooker
Cushioning material
GB - 5