Redring Xpressions eco-t Handbook

Redring Xpressions eco-t Handbook

Thermostatic instantaneous electronic shower

Advertisement

GUARANTEE
Terms and Conditions for UK (outside UK contact your local distributor)
I
We, Redring Xpelair Group Ltd., guarantee this product for domestic use only, for the period of 24
months from the date of purchase.
I
Within the guarantee period we will resolve, free of charge, any manufacturing defects in the product
resulting from faulty workmanship or material on the condition that:
I
A) The appliance has been correctly installed in accordance with our instructions and is being used on the supply
circuit or voltage printed on the rating plate.
I
B) The appliance has been used in accordance with these instructions and has not been tampered with or
otherwise subject to misuse, neglect or accident.
I
C) The appliance has not been taken apart, modified or repaired except by a person authorised by us.
I
D) Evidence of the date of purchase in the form of an invoice or receipt will be required in order to qualify for an
in-guarantee repair.
I
E) The guarantee period for the products used in commercial applications will be limited to 12 months.
I
F) For the service work to be undertaken free of charge, the work must be only undertaken by
Redring Xpelair Group Limited, or our approved agents.
I
G) Service under guarantee has no effect on the expiry date. The guarantee on any exchanged parts or product
ends when the original guarantee period ends.
EXCLUSIONS
This guarantee DOES NOT cover damage or defects arising from poor or incorrect installation, improper use or lack of maintenance,
including build-up of limescale. It is the responsibility of the installer to check that the installation parameters meet the requirements
of the product, and any relevant regulations.
I
If we are called out to a fault, which is subsequently identified as being an installation fault, we will make a charge. It is important
that the routine checks are completed before calling us out, as many issues can be simply diagnosed and resolved.
I
We make no guarantees as to response times for repairs. We will endeavour to achieve the most timely response possible but while
we indicate an average response time, this should not be taken as a guarantee.
I
The guarantee applies to a repair or replacement (at our discretion) of the product subject to the conditions above, and DOES NOT
cover compensation for the loss of the product or consequential loss of any kind
The guarantee does not apply to the repair or replacement of pressure relief devices, sprayheads, hoses, accessories, isolating
switches, electrical cable, fuses and/or circuit breakers.
I
This guarantee does not affect your statutory rights.
After Sales Service
We offer a technical advisory service on the telephone to installers and other customers with problems
in the field.
I
RING 0844 372 7766 (UK ONLY)
I
Remember to quote type of shower, as written on the front of the shower and on this leaflet.
I
The model and serial number are located on the bottom face of the shower.
Make a note of those numbers here, and be sure to quote them if you call for advice.
I
Model Number: 53--__________________ / Serial Number:____________________
Note: You may be charged for a service call if you do not have the serial number.
Full details of terms and conditions are available on request from:-
Redring Xpelair Group, Newcombe House,
Newcombe Way, Orton Southgate, Peterborough, PE2 6SE
Website: www.redring.co.uk
A3:567-2450-01 Rev B
I
16
Xpressions
Thermostatic Instantaneous Electronic Shower
Handbook
Installer
Information
Installation Instructions
Plumbing Connections
Electrical Connections
Commissioning
Trouble Shooting (Installer)
Spares
IMPORTANT
This booklet should be given to the customer after installation and demonstration
Contents
User
Page
Information
2
How To Start Your Shower
3
How To Operate Your Shower
5
How your shower works
7
Handset Operation
14
Routine Maintenance
15
Periodical Maintenance
Trouble Shooting (User)
Guarantee
Page
8
9
10
12
12
13
13/14
16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Xpressions eco-t and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Redring Xpressions eco-t

  • Page 1 Xpressions Terms and Conditions for UK (outside UK contact your local distributor) We, Redring Xpelair Group Ltd., guarantee this product for domestic use only, for the period of 24 months from the date of purchase. Within the guarantee period we will resolve, free of charge, any manufacturing defects in the product...
  • Page 2 Installation Instructions A TYPICAL INSTANTANEOUS ELECTRIC SHOWER INSTALLATION Spares (Ring 0844 372 7750 UK ONLY) ALL WIRING AND INSTALLATION MUST BE Please Note:- The fitting of all spares should be supervised by a suitably qualified person SUPERVISED BY A SUITABLY QUALIFIED Description Description Part No,...
  • Page 3: Plumbing Connections

    Plumbing Connections Switch OFF electricity at ceiling/wall isolating switch, d) Lights behaves erratically. Diagram 2 Plumbing to be carried out before wiring wait a few seconds, switch on again. (Note: The shower should be switched OFF each DO NOT use jointing compounds on any pipe time after use at the ceiling/wall isolating switch.
  • Page 4 Connect the mains water supply to the Inlet of the shower via 15mm copper, stainless steel or plastic Periodical Maintenance pipe using a 15mm compression fitting. See (Diagram 4) for advice on Rear Entry fitting. Diagram 21 The Inlet fitting is designed to rotate through 180° to allow for either Top or Bottom/Rear entry fitting Cleaning the Filter (See Diagrams 3).
  • Page 5: Routine Maintenance

    If you are replacing an existing shower you will Handset Operation need to remove the appropriate backplate There are six spray plate setting modes (patterns) section subject to whether the mains water adjustable by rotating the spray plate (see Diagram 20). plumbing approach is either top or bottom These modes (patterns) have a positive click to identify entry.
  • Page 6 entry points then the following backplate component will need to be discarded allowing for the Stage two only operates if an extreme temperature is sensed. The cut out will permanently conduit to fit into the backplate. See Diagram 5 - Option ‘E’ or ‘F’. switch off and it will then have to be replaced.
  • Page 7: How Your Shower Works

    While this is happening the relevant blue LED the cover. will flash. PLEASE NOTE! The Xpressions Eco-T is The unit will then switch off automatically. factory set with the outlet temperature limit of TEMPERATURE...
  • Page 8 Allow the unit to fill and wait for the water to START IN TIMED Diagram 10 come out of the handset then press the ECO SETTING Stop/Start button turning the shower OFF See Diagram 10 Re-start - Press Start /Stop Button. See Diagram 10 Check that the outlet temperature increases.

Table of Contents