23. UPDATING FIRMWARE
TI (DSP) BOOT?: Not applied to these models.
USB UP:START?: The writing mode of sub-microproces-
sor (NET P.C.B.) firmware.
Tools required
USB flash memory
Firmware (RX-N600.tar)
Operation procedure
1. Download the latest firmware from the specified down-
load source to PC.
2. Copy the latest firmware into the root folder of the USB
flash memory.
Caution) When the firmware is copied into the
sub-folder, it is not possible to write data
in it.
3. Insert the USB flash memory to the USB terminal of this
unit.
4. Start the DIAG function.
5. Select the DIAG menu "23-2 USB UP: START?".
6. Press the "STRAIGHT" key to start writing.
7. Writing is completed when "USB UP: OK" is displayed.
50
23. UPDATING FIRMWARE
TI (DSP) BOOT? : このモデルには適用されません。
23.TI BOOT ?
USB UP : START? : サブマイコン (NET P.C.B.) のファームウェア
書き込みモー ドです。
USB UP:START?
必要なツール
USB フラッシュメモリー
ファームウェア (RX-N600.tar)
操作手順
1. PCへの指定のダウンロー ド先から最新のファームウェアをダウン
ロー ドしてく ださい。
2. 最新のファームウェアをUSBフラッシュメモリーのルー トフォルダ
にコピーします。
注意) ファームウェアをサブフォルダにコピーした場合、 書き込み
できません。
3. 本機のUSB端子にUSBフラッシュメモリーを差し込みます。
4. DIAGを起動します。
5. DIAG 23-2 "USB UP : START?" を選択します。
USB UP:START?
6."STRAIGHT" キーを押して、 書き込みを開始します。
USB UP:WAITING
Writing being prepared. /
USB UP:xxx%
Data being written. /
7."USB UP : OK" が表示されたら、 書き込み完了です。
USB UP:OK
書き込み準備中。
書き込み中。