Electrical Connection - Smeg SA611XA-1 Directions For Use Manual

Highlight ceramic hob
Table of Contents

Advertisement

ELECTRICAL CONNECTION

 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and
which respects them scrupulously.
 Protection against the parts under tension must be ensured after the building-in.
 The data of connection necessary are on the stickers place on the hob casing near the
connection box.
 The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for
example: circuit breakers, fuses or contactors.
 If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
 The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
Mains
230V~1N 50Hz 1 Phase + N
400V~2N 50Hz 2 Phases + N
( * ) calculated with the simultaneous factor following standard TN 60 335-2-6/1990
Caution!
This appliance has only to be connected to a network 230 V~ 50 Hz
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use
a medium screwdriver. Place it in the slits and open the cover.
Connection of the hob
The ceramic hob can be connected in different ways:
Monophase 230V~1P+N
Biphase
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put the bridge between terminal 1 and 2
Attach the earth to the terminat "earth", the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase
400V~2P+N
Attach the earth to the terminat "earth", the neutral N to terminal 4, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Caution! Ensure that you:
- Correctly attach the wires and the bridges.
- Tighten the screws properly.
Before making the connection, we strongly advise you to locate the phase(s), neutral and
earth on the mains. If you have any doubts, call your electrician.
Note: the bridge between terminals 1 and 2 is installed during the factory check.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
Connection
Cable diameter
3 x 2,5 mm²
4 x 1.5 mm²
400V~2P+N
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
11
Protection calibre
25 A *
16 A *