Section 8: Installing & Removing the Door
Removing the door:
The L42DF-ST* doors are removed in a few simple steps. Follow these
instructions below to remove the Horizontal access panel, unlatch
the door buckles and, remove the door. Replace in reverse order.
WARNING
When reinstalling door(s), always make sure all door
buckles are properly hooked and fully engaged.
Step 1:
Remove the Horizontal cover
by placing fingers in both
finger holes, then pushing
away from you and lifting
out. Place it aside during
maintenance or cleaning.
Install in reverse order.
Figure 23. Removing and installing the Horizontal Access Panel
Step 2:
Locate the Door Buckles.
Figure 23a. Locate the door buckles. Both sides typical.
Step 3:
Locate Door Buckle Tool.
Hand-hold
Figure 23b. Door buckle Tool
XG0182 -151126
Installation
Finger Holes
Installed Gas
Valve Cove r
Door Latch Slot
Door Latch Hook
Step 4:
Firmly grasp hand-hold
end of Door buckle tool
and place the machined
end in the slot under
door frame. (as shown)
Figure 23c.
Step 5:
Ensure the tool is firmly
in the lower end of the
slot, (as shown), Then pull
toward you (Caution: hold
the tool securely).
Figure 23d.
Step 6:
Pull hard if necessary
to release the spring
tension. (Caution: The
latch springs back with
force, hold the tool
securely).
Figure 23e.
Step 7:
Remove the tool from
the latch slot. Ensure the
latches are hanging freely,
the hook end is released
from the bottom of the door.
(Repeat all 4-steps for the
remaining latches).
Figure 23f.
L42DF-ST* Indoor Gas Fireplace
1
2
3
4
Page 25

Hide quick links: