Montigo L42DF ST Installation & Maintenance Manual page 21

L-series indoor residential fireplace
Table of Contents

Advertisement

Installing the remote On/Off Wall Switch
The L42DF-ST* gas valve may be connected to a wall switch. Do
NOT connect any external power to the remote switch. The valve
will generate its own power on a millivolt circuit or will draw its
power from an AC Connection inside the fireplace, depending on
the model of the unit. Use only low voltage wire, and DO NOT
connect any external power to the remote switch.
Refer to Figure 16 or 17 for wiring requirements.
NOTE: The switch location must not exceed 30' from the fireplace.
NOTE: If any of the original wire supplied with the appliance is replaced,
it must be replaced with the same type, or its equivalent.
5
3
8 "
1
8
2 "
Figure 19. Electrical connection access
XG0182 -151126
Installation
7
8 "
L42DF-ST* Indoor Gas Fireplace
Page 21