Set Delay Compensation Switch
5
Single Radiator Systems
5A
The position of the delay compensation switch does not matter in single radiator systems.
Multiple Radiator Systems
5B
It is necessary to select the correct delay compensation switch
setting for each radiator to ensure that each radiator transmits
the same signal at exactly the same time in an overlapping
,multiple radiator system. Not setting the delay compensation
switch correctly will result in reduced coverage area for the
system. See designing a system page 14 for determining the
correct delay compensation switch setting for each radiator
in a multiple radiator system.
6
Set Termination Switch
Single Radiator Systems
6A
Multiple Radiator Systems
6B
Set the termination switch to the "OFF" position on all radiators
that are outputting an RF signal to another radiator.
Set the termination switch to the "ON" position on the radiators
that are not outputting an RF signal to another radiator.
Set LED Indicator Shutoff Switch (SW1)
7
If desired, the three LED indicators on the front of the radiator can be disabled using this switch. Set this
switch to the "OFF" position towards the left side of the rear of the radiator to disable the LED indicators.
To enable the LED indicators set this switch to the "ON" position towards the right side of the rear of the radiator.
l
36
Delay Compensation Switch
Always set the termination switch to the "ON" position in single radiator systems.
Termination Switch
LED Indicator Shutoff Switch (SW1)