6. FAQ

Q1: What voltage that VC-201A / VC-202A / VC-204 used?
A1: 5V DC, 2A
Q2: What is VDSL2?
A2: VDSL2 (Very High-Bit-Rate Digital Subscriber Line 2),
G.993.2 is the newest and most advanced standard of
xDSL broadband wire line communications.
Designed to support the wide deployment of Triple Play
services such as voice, data, high definition television
(HDTV) and interactive gaming, VDSL2 enable opera-
tors and carrier to gradually, flexibly, and cost efficiently
upgrade exiting xDSL-infrastructure.
Q3: What is the best distance for VC-201A / VC-202A / VC-
204?
A3: In order to guarantee the stability and better quality of
network, so we would suggest the distance within 1.6 kilo-
meter is the best for VC-201A / VC-204 and 3.0kilometer
for VC-202A.
Q4: What is the best date rate for VC-201A / VC-202A / VC-
204?
A4: We provide the data rate of the VC-201A / VC-204 is up
to 100Mbps/55Mbps and the VC-202A is up to 100Mbps/
65Mbps (downstream / upstream) in 200 meters
Q5: Can VC-201 compatible with VC-201A / VC-204?
A5: Currently NO. Although VC-201 (profile 12a) and VC-201A
/ VC-204 (profile 17a) are base on ITU-T G.993.2 VDSL2,
but with different Profiles, so far they are not compatible
with each other.