Tool Protection & Care - Stanley CS11 User Manual

Hide thumbs Also See for CS11:
Table of Contents

Advertisement

Make sure all couplers are wiped clean before con-
nection.
The hydraulic circuit control valve must be in the
"OFF" position when coupling or uncoupling hydrau-
lic tools. Failure to do so may result in damage to
the quick couplers and cause overheating of the hy-
draulic system.
Always store the tool in a clean dry space, safe from
damage or pilferage.
Make sure the circuit PRESSURE hose (with male
quick disconnect) is connected to the "IN" port. The
circuit RETURN hose (with female quick disconnect)
is connected to the opposite port. Do not reverse cir-
cuit flow. This can cause damage to internal seals.
Always replace hoses, couplings and other parts
with replacement parts recommended by Stanley
Hydraulic Tools. Supply hoses must have a mini-
mum working pressure rating of 2500 psi/172 bar.
18 ► CS11 User Manual
TOOL PROTECTION & CARE
NOTICE
In addition to the Safety Precautions found in
this manual, observe the following for equipment
protection and care.
Do not exceed the rated flow and pressure. See
Specifications page in this manual for correct flow
rate and pressure rating. Rapid failure of the internal
seals may result.
Always keep critical tool markings, such as warning
stickers and tags legible.
Tool repair should be performed by experienced
personnel only.
Make certain that the recommended relief valves
are installed in the pressure side of the system.
Do not use the tool for applications for which it was
not intended.