Control Operation During A Power Failure
In the event of a power failure, the valve will keep track of the time and day for 48 hours.
The programmed settings are stored in a non-volatile memory and will not be lost during a
power failure. If power fails while the unit is in regeneration, the valve will finish regenera-
tion from the point it is at once power is restored. If the valve misses a scheduled regen-
eration due to a power failure, it will queue a regeneration at the next regeneration time
once power is restored.
Main Display
The main display page will pause on the Date and Time page for 5 seconds. Then it will
continually scroll through all of the system diagnostic display pages. Depending on the
Valve Type some pages will not be displayed. To manually scroll through the diagnostics,
press the down or up key. To reset the TOTAL REGENS, TOTAL GALLONS OVER RUN TO-
TAL, or PEAK flow rates, press and hold the MENU until the value changes to zero.
PARAMETER
JULY/17/2012
8:30 PM
TOTAL 1,500 GAL
REMAIN 1,200 GAL
LAST REGEN
9/24/12
TOTAL REGENS
10
TOTAL GALLONS
001590 GAL
TOTAL 4 DAYS
REMAIN 3 DAYS
OVER RUN TOTAL
0000 GAL
CURRENT 1.5 GPM
PEAK 6.5 GPM
DELAYED REGEN
OFF
REGEN TIME
12:00 AM
VALVE MODE
B.W. FILTER
Regeneration Process
Periodically the filter will require a back wash to clean the trapped particles and unpack the
filter bed to restore the system flow rates. The table below explains the regeneration steps.
Step
Name
#1
Back Wash
#2
Rinse

About The System

DESCRIPTION
Month, Day, Year, Time
The total amount is the system capacity when fully regenerated.  The remaining is the 
capacity left in the system.
The date of the last regeneration.
The total number of regenerations.
The total amount of gallons treated by the system.
The number of days remaining before regeneration.  This option is only in filter mode.
The total amount of water that has exceeded the system capacity over the last 4 
regenerations.  When remaining goes to zero, the gallons used will be added to over run total.
The current flow rate and the peak flow rate since the last regeneration.
Advises whether a delayed regeneration has been scheduled manually or automatically.
The current setting for regeneration time.
The current setting of the valve mode.
Description
Fresh water is introduced to the bottom of the tank flowing upwards expanding 
the filter media to rinse out any dirt or small particles to the drain and to un‐
compact the bed to restore full service flow rates.
Fresh water is introduced from the top of the tank flowing down through the 
filter bed rinsing any unfiltered water to the drain.