NEVER CONNECT AN UNREGULATED GAS SUPPLY
LINE TO THE APPLIANCE. USE THE
REGULATOR/HOSE ASSEMBLY SUPPLIED.
This is a liquid propane configured grill. Do not attempt
to use a natural gas supply unless the grill has been
reconfigured for natural gas use.
Total gas consumption (per hour) of this stainless steel
gas grill with all burners on "HI"
Main burner
40,000 Btu/hr
Side burner
12,000 Btu/hr
Rear burner
10,000 Btu/hr
Total
62,000 Btu/hr.
L.P. TANK REQUIREMENT
A dented or rusty L.P. tank may be hazardous and
should be checked by your L.P. supplier. Never use a
cylinder with a damaged valve. The L.P. gas cylinder
must be constructed and marked in accordance with the
specifications for L.P. gas cylinders of the U.S.
Department of Transportation (DOT) or the National
Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes for Transportation of Dangerous
Goods; and Commission, as applicable. Overfilling
prevention device (OPD) shall be provided on cylinder &
QCCI connection on the cylinder valve, ANSI/CGA-V-1.
The cylinder supply system must be arrange for vapor
withdrawal. The cylinder must include a collar to protect
the cylinder valve. The cylinder must be provided with a
shut off valve terminating in an L.P. gas supply cylinder
valve outlet specified, as applicable, for connection type
QCC1 in the standard for compressed gas cylinder
valve outlet and inlet connection ANSI/CGA-V-1.
Manifold pressure: 11"(27.94cm) water column (W.C.).
L.P. GAS HOOK-UP
Ensure that the black plastic grommets on the LP
cylinder valve are in place and that the hose does not
come into contact with the grease tray or the grill head.
CONNECTION
Your stainless steel grill is equipped with gas supply
orifices for use only with liquid propane gas. It is also
equipped with a high capacity hose/regulator assembly
for connection to a standard 20lb. L.P. cylinder (18-1/4"
(46.35cm) high, 12-1/4"(31cm) diameter). To connect
the L.P. gas supply cylinder, please follow the steps
below:
1. Make sure tank valve is in its full off position (turn
clockwise to stop)
2. Check tank valve to assure it has proper external
male threads (type 1 connection per ANSIZ21.81)
3. Make sure all burner valves are in their off position.
4. Inspect valve connections, port, and regulator
assembly. Look for any damage or debris. Remove
any debris. Inspect hose for damage. Never
attempt to use damaged or obstructed equipment.
See your local L.P. gas dealer for repair.