M/Min; - Lincoln Electric PF42 Operator's Manual

Hide thumbs Also See for PF42:
Table of Contents

Advertisement

Advanced Menu (Device Configuration Menu)
The Advanced Menu includes the parameters described in Table 7.
Table 7. The default settings of Advanced Menu
English
The Menu Exit – enables exit from menu.
Note: This parameter cannot be edited.
To exit from menu:
In Advanced Menu select P000.
Confirm the selection, push the right button.
Wire Feed Speed (WFS) units – enables change WFS units:
CE (factory default) = m/min;
US = in/min.
Arc Display Mode - this option selects what value will be
shown on the upper left display while welding:
"Amps" (default) = The left display shows Amperage while
welding.
"WFS" = The left display shows Wire Feed Speed while
welding.
Crater Delay - this option is used to skip the Crater sequence
when making short tack welds. If the trigger is released before
the timer expires, Crater will be bypassed and the weld will
end. If the trigger is released after the timer expires, the Crater
sequence will function normally (if enabled).
OFF (0) to 10.0 seconds (default = OFF)
Remote Control Type - This option selects the type of analog
remote control being used. Digital remote control devices
(those with a digital display) are configured automatically.
"TIG" = Use this setting while TIG welding with a foot or
hand current control device (Amptrol). While TIG welding,
the upper left Control on the User Interface sets the
maximum current obtained when the TIG amp control is at
its maximum setting.
"Stick" = Use this setting while stick welding or gouging
with a remote output control device. While stick welding,
the upper left Control on the User Interface sets the
maximum current obtained when the stick remote is at it's
maximum setting. While gouging, the upper left Control is
disabled and the gouging current is set on the remote
control.
"All" = This setting allows the remote control to function in
all weld modes which is how most machines with 6-pin and
7-pin remote control connections operate.
"Joys" (default) = Use this setting while MIG welding with a
push MIG gun with a joystick control. Stick, TIG and gouge
welding currents are set at the User Interface.
Note: On machines that do not have a 12-pin connector, the
"Joys" settings will not appear.
Display Trim as Volts Option – determines how Trim is
displayed:
"Yes" (factory default) = all trim values are displayed as a
voltage;
"No" = the trim is displayed in the format defined in the
weld set.
Note: This option may not be available on all machines. The
power source must support this functionality, or this option will
not appear in the menu.
12
English

Hide quick links: