To Service Personnel - Yamaha HTR-6150 Service Manual

Av receiver/av amplifier
Hide thumbs Also See for HTR-6150:
Table of Contents

Advertisement

RX-V563/HTR-6150/DSP-AX563
I TO SERVICE PERSONNEL
1. Critical Components Information
Components having special characteristics are marked s and
must be replaced with parts having specifications equal to those
originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
G
Meter impedance should be equivalent to 1500 ohms shunted
by 0.15µF.
For U model
"CAUTION"
"F3401, F3402: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME
For C model
CAUTION
F3401, F3402: REPLACE WITH SAME TYPE 6A, 125V FUSE.
ATTENTION
F3401, F3402: UTILISER UN FUSIBLE DE RECHANGE DE MÉME TYPE DE 6A, 125V.
WARNING: CHEMICAL CONTENT NOTICE!
This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive
harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY
REASON WHAT SO EVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose
eyes to solder/flux vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.
About lead free solder
All of the P.C.B.s installed in this unit and solder joints are soldered using the lead free solder.
Among some types of lead free solder currently available, it is recommended to use one of the following types for the repair
work.
• Sn + Ag + Cu (tin + silver + copper)
• Sn + Cu (tin + copper)
• Sn + Zn + Bi (tin + zinc + bismuth)
Caution:
As the melting point temperature of the lead free solder is about 30°C to 40°C (50°F to 70°F) higher than that of the lead solder, be sure
to use a soldering iron suitable to each solder.
2
TYPE 6A, 125V FUSE."
WALL
EQUIPMENT
OUTLET
UNDER TEST
INSULATING
TABLE
G
Leakage current must not exceed 0.5mA.
G
Be sure to test for leakage with the AC plug in both polarities.
AC LEAKAGE
TESTER OR
EQUIVALENT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsp-ax563Rx-v563

Table of Contents