MAINTENANCE

WARNING:
Power must be turned off for all checking and maintenance, before opening the housing, make sure
the power plug is disconnected.
1.
Remove dust by dry and clean compressed air regularly, if welding machine is operating in environment where is
polluted with smokes and pollution air, the machine need removing dust everyday.
2.
Pressure of compressed air must be inside the reasonable arrangement in order to prevent damaging to small
components of inter-machine.
3.
Check inter circuit of welding machine regularly and make sure the cable circuit is connected correctly and
connectors are connected tightly (especially insert connector and components). If scale and loose are found, please
give a good polish to them, then connect them again tightly.
4.
Avoid water and steam enter into inter-machine, if they enter into machine, please dry inter-machine then check
insulation of machine.
5.
If welding machine will not be operated long time, it must be put into packing box and store in dry environment.
6.
When wire machine operates for every 300 hours, the electric carbon brush and armature rectifier should be
polished, the reducer should be cleaned, and lubricator should be added to the turbo and bearing.

NOTES BEFORE CHECKING

Blind experiment and careless repair may lead to more problems and make formal check and repair more
difficult. When the machine is electrified, the bared parts contain life-threatening voltage. Any direct and indirect
touch will cause electric shock, and severe electric shock will lead to death.
NOTICE: In the period of guarantee maintenance, if user makes wrong check and repair for malfunction
of welding/cutting machines without our permission, the free maintenance guarantee offered will be invalid