Clearances - Monessen Hearth SS38 Installation And Operating Instructions Manual

Direct vent gas stove
Table of Contents

Advertisement

SS38 Direct Vent Gas Stove
CLEARANCES TO COMBUSTIBLES
The dimensions shown in Figures 4 and 5 are minimum clearances to maintain
in installing this heater. Left and right clearances are determined when facing the
front of the heater.
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material
other than wood flooring. If installed on carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or noncombustible material panel extending
full width and depth of the appliance.
Maintain the following minimum clearances for service and maintenance.
Stove must be at least 6" from the back wall. Figure 4
Stove must be at least 9" from either side wall. See Figure 4
Stove must be at least 6" from the corner. Figure 4
No clearance is necessary to the floor. Stove may sit on the floor. Figure 5
The minimum ceiling height from the floor must be 72".
Back Wall
9"
Minimum
to Either
Side Wall
Figure 4 -
Clearances to Side, Back and Adjacent Walls
8
6" Min.
6" Minimum
Clearance to
Corner
ST1101

clearances

Figure 5 -
Clearance to Floor
ST1102
floor clearance
CLEARANCES
0"
ST1102
46D0232