WARNINGS
IF THE INFORmATION IN THESE INSTRUCTIONS
ARE NOT FOLLOWED ExACTLy, A FIRE
OR ExpLOSION mAy RESULT CAUSING
pROpERTy DAmAGE, pERSONAL INjURy OR
LOSS OF LIFE.
– Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
– WHAT TO DO IF yOU SmELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
– Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WARNING: Improper installation, adjustment,
alteration, services or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information
consult a qualified installer, service agency or
the gas supplier.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
This appliance may be installed in an aftermarket*,
permanently located, manufactured home,
where not prohibited by local codes.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
INSTALLER: Leave this manual with the appliance.
CONSUmER: Retain this manual for future refer-
ence.
READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONS
Direct Vent Gas Stove
Installation and Operating
Instructions
models:
CSDV20SNV,CSDV20DNV,CSDV20SLp,CSDV20DLp,
CSDV30SNV,CSDV30DNV,CSDV30SLp,CSDV30DLp,
CSDV40SNV,CSDV40NDV,CSDV40SLp,CSDV40DLp
D U E T O H I G H T E m p E R AT U R E S , T H E
AppLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC AND AWAy FROm FURNITURE AND
DRApERIES.
CHILDREN AND ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH SURFACE
TEmpERATURE AND SHOULD STAy AWAy TO
AVOID BURNS OR CLOTHING IGNITION.
yOUNG CHILDREN SHOULD BE SUpERVISED
WHEN THEy ARE IN THE SAmE ROOm AS THE
AppLIANCE.
CLOTHING OR OTHER FLAmmABLE mATERIAL
SHOULD NOT BE pLACED ON OR NEAR THE
AppLIANCE.
KEEp THE ROOm AREA CLEAR AND FREE
FROm COmBUSTIBLE mATERIALS, GASOLINE,
AND OTHER FLAmmABLE VApORS AND
LIqUIDS.
586056
CSDV cover
58D6056 2/10 Rev. 7
O N
O FF

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CSDV20SLP and is the answer not in the manual?

Questions and answers

Summary of Contents for Monessen Hearth CSDV20SLP

  • Page 1 READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONS Direct Vent Gas Stove Installation and Operating Instructions models: CSDV20SNV,CSDV20DNV,CSDV20SLp,CSDV20DLp, CSDV30SNV,CSDV30DNV,CSDV30SLp,CSDV30DLp, CSDV40SNV,CSDV40NDV,CSDV40SLp,CSDV40DLp D U E T O H I G H T E m p E R AT U R E S , T H E 586056...
  • Page 2: Table Of Contents

    Installation for Horizontal Termination ... 15 Installation for Vertical Termination ... 18 Stove Installation ... 22 Check Gas Type... 22 Install Gas Piping to Stove Location ... 23 Checking Gas pressure ... 24 Electrical Installation... 24 Electrical Wiring ... 24 Remote Wall Switch ...
  • Page 3: Important Safety Information

    Do not run burner system where these are used or stored. Do not place items such as clothing or decorations on or around stove. 12. Do not use this stove to cook food or burn paper or other objects. 13. Never place anything on top of stove.
  • Page 4: Code Approval

    18. Do not use stove if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit.
  • Page 5: Product Features

    GAS SpECIFICATIONS & ORIFICE SIZE model CSDV20NV CSDV20PV CSDV30NV CSDV30PV Propane (LP) CSDV40NV 11.0” w.c. CSDV40PV 13.0” w.c. 10.0” w.c. CSDV Series Direct Vent Gas Stove On/Off Switch Ignitor Box Located Under Right Front Leg Door FP2724 CSDV controls max.Input min. Input Fuel...
  • Page 6: Stove Dimensions

    CSDV Series Direct Vent Gas Stove Figure 2 - Stove Dimensions Ref. CSDV20 20M\," 23Z\x" 18C\v" CSDV30 (530 mm) 26Z\x" (673 mm) (597 mm) 28Z\x" (724 mm) 586056 (476 mm) 21" (533 mm) CSDV dims STOVE DImENSIONS CSDV40 29Z\x" (749 mm) 30Z\x"...
  • Page 7: Stove Location

    This stove should have sufficient access for its safe operation and maintenance. • Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building. e.g. cutting wall or ceiling joist (example: load-bearing framing members).
  • Page 8: Clearances

    CSDV Series Direct Vent Gas Stove CLEARANCES TO COmBUSTIBLES The dimensions shown in Figures 4 and 5 are minimum clearances to maintain in installing this heater. Left and right clearances are determined when facing the front of the heater. Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.
  • Page 9: Clearances / Height Requirements

    Alcove minimum Dimensions Height from Hearth Width 52" (1321 mm) 30" (762 mm) 64" (1626 mm) 35" (889 mm) 64" (1626 mm) 35" (889 mm) CSDV Series Direct Vent Gas Stove ST1132 Depth 36" (914 mm) 36" (914 mm) 36" (914 mm)
  • Page 10: Remove Unit From Crate

    CSDV Series Direct Vent Gas Stove 1. Remove two (2) straps. Figure 6 2. Open plastic bag and slide to bottom of unit. Figure 7 3. Lift up on ash lip and pivot down to open control door. Figure 8 4.
  • Page 11: Venting Installation

    Installation of any component part not manufactured or approved by MHSC. • Installation other than permitted by these instructions. This stove must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance.
  • Page 12: Installation Planning

    FOR VERTICAL TERmINATION Measure the distance from the stove flue outlet to the ceiling. Add the ceiling thickness, the verti- cal rise in an attic or second story, and allow for sufficient vent height above the roof line. You may use one or two 90°...
  • Page 13: General Venting Information - Termination

    < 100,000 Btuh (30kW), 36” (91 cm) for appliances > 100,000 BTU/h (30kW) 6’ (1.83 m) 7’ (2.13 m)† 12” (30 cm) NOTE: 1. Local codes or regulations may require different CSDV Series Direct Vent Gas Stove H  V  B  M  I ...
  • Page 14: Termination Clearances

    CSDV Series Direct Vent Gas Stove Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Combustible Noncombustible Balcony - with no side wall Figure 12 - Allowable Venting Combustible & Noncombustible 12" (305 mm) *NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits.
  • Page 15: Installation For Horizontal Termination

    Minimum Figure 16 - Rigid Vent Pipe Connections 3. Attach vent pipe assembly to the stove. Set stove in front of its permanent location to insure minimum clear- ances. Mark the wall for a 9Z\x" (241 mm) square hole (for noncombustible material such as masonry block or concrete, a 7Z\x"...
  • Page 16 5. Slide the wall thimble over the vent pipe before con- necting the horizontal run to the vent cap. Figure 20 6. Carefully move the stove with vent assembly attached Framing Detail toward the wall and insert the vent pipe into the hori- zontal termination.
  • Page 17 Table 3 - Horizontal Venting with Two (2) 90° Elbows maximum Horizontal H + H 24" (610 mm) (6 m) NOTE: Add 1/4" rise per 12" horizontal length of pipe. ST1140 CSDV Series Direct Vent Gas Stove Vertical Vertical Vertical minimum minimum minimum CSDV20 (V) CSDV30 (V) CSDV40 (V) 41Z\x"...
  • Page 18: Installation For Vertical Termination

    Offsets must fall within the parameters shown on Page 14, Figure 13. 2. Set stove in desired location. Drop a plumb line down from the ceiling to the position of the burner system exit flue. Mark the center point where the vent will penetrate the ceiling.
  • Page 19: Cathedral Ceiling Installation

    Mark the outline of the cathedral ceiling support box on the roof sheathing using the locating hole as a center point. 2. Cut the hole 1/8" larger than the support box outline. Figure 27. CSDV Series Direct Vent Gas Stove...
  • Page 20 (6 m) Figure 29 - Vertical Rigid Venting Configuration using Three (3) 90° Elbows with Two (2) Horizontal Runs VENTING INSTALLATION NOTE: Install restrictor into 4" collar of stove or first vent section as shown. Vertical ST1145 minimum minimum Vert vent 3 elbows...
  • Page 21 98C\v" 102Z\v" Vertical Rigid Venting Configuration with (2597 mm) No Horizontal Run Number 943S 945B 990B CSDV Series Direct Vent Gas Stove NOTE: Install restrictor into 4" collar of stove or first vent section as shown. ST1147 ST1147 vert vent Description Roof Flashing 7/12 - 12/12 6B\,"...
  • Page 22: Stove Installation

    A qualified installer or service person must connect appliance to gas supply. Follow all local codes. INSTALLATION ITEmS NEEDED Before installing stove and burner system, make sure you have the items listed below. • External regulator (supplied by installer) •...
  • Page 23: Install Gas Piping To Stove Location

    CSA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap* Tee Joint 3 "   M i n i CSDV Series Direct Vent Gas Stove Natural Gas From Gas Meter (5.0" w.c. to 10.5" w.c. Pressure) propane/Lp From External Regulator (11,0" w.c. to 13.0" w.c. Pressure)
  • Page 24: Checking Gas Pressure

    Do not over torque. Check test points for gas leaks. ELECTRICAL WIRING This stove will work without any electrical supply. Electricity is only needed to operate blower. NOTE: If installed in mobile home, fireplace must be bolted securely to floor.
  • Page 25: Electrical Installation

    (diameter) wire. Always check with local code. PILOT TH/TP Figure 35 - Wiring Diagram for Wall Switch 58D6056 ST1148 wiring diagram CSDV Series Direct Vent Gas Stove OPTIONAL REMOTE WALL SWITCH...
  • Page 26: Log And Rock Wool Placement

    CSDV Series Direct Vent Gas Stove Before you begin — This unit is supplied with ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the logs, wash your hands gently with soap and water to remove any traces of fibers.
  • Page 27: Log Placement

    Do not place rock wool on rear of burner. Top Right Log #5 Right Base Log #3 Rock Wool Rear Log Figure 39 - Place CSDV30 Rock Wool LG816 Pins CSDV Series Direct Vent Gas Stove P IL LG817 LG816 CSDV30 rockwool...
  • Page 28 CSDV Series Direct Vent Gas Stove pLACE CSDV40 LOGS IN FIREBOx Figure 40 1. Carefully remove logs from wrapping. 2. Open front door of firebox. 3. Place rear log (#1) on rear log pins. 4. Place left base log (#2) on the two pins against left side of firebox.
  • Page 29: Operating Instructions

    58D6056 If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. CSDV Series Direct Vent Gas Stove...
  • Page 30: Lighting Pilot For The First Time

    The control has an interlock device that does not allow the lighting of the stove up to the moment the safety device of the flame has not interrupted the gas flow. After that period of time (when the magnet is closed), it is possible to start the lighting operation.
  • Page 31: Lighting Burner

    The “ON/OFF” switch for the main burner can be found on the back right side of the stove. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON”...
  • Page 32: Air Shutter Adjustment (Natural Gas Only)

    1/4" for Natural Gas and fully open for Propane installation at sea level. Natural Gas Models may be adjusted for high altitude as follows: • To increase air mixture, pull down the adjustment rod located beneath the stove. This opens the shutter more and will stop sooting. Figure 47 •...
  • Page 33: Cleaning And Maintenance

    Carefully reassemble and reseal stove properly after any cleaning or servicing. 58D6056 CSDV Series Direct Vent Gas Stove Allow glass to cool before cleaning. Do not clean glass when it is hot. Damage could occur. Thermocouple...
  • Page 34: Glass Replacement

    1. Put on gloves. 2. Remove door from stove. Page 10 3. Remove glass from stove by releasing two clamps on bottom of stove. Lift glass frame up and off the unit. Figure 51 4. Carefully remove broken glass. 5. Wrap new glass pane with tadpole gasket. Make sure you have 1/4"...
  • Page 35: Troubleshooting

    3. Thermostat set too low/defec- tive 1. Normal condition 1. Normal during start up 1. Flame impingement CSDV Series Direct Vent Gas Stove REmEDy 1. Replace battery 2. Check connections to ignitor. Replace ignitor if ignitor connections are good, but there is no spark.
  • Page 36: Replacement Parts

    REpLACEmENT pARTS CSDV Series Direct Vent Gas Stove CSDV20 Replacement parts 20  586056 CSDV20 parts 58D6056...
  • Page 37 Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 58D6056 qty. CSDV Series Direct Vent Gas Stove CSDV20NV CSDV20pV 58D0250 58D0250 58D0210 58D0210...
  • Page 38: Csdv30

    CSDV Series Direct Vent Gas Stove CSDV30 Replacement parts 586056 CSDV30 parts REpLACEmENT pARTS 20  58D6056...
  • Page 39 Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 58D6056 qty. CSDV Series Direct Vent Gas Stove CSDV30NV CSDV30pV 58D0150 58D0150 58D0024 58D0024...
  • Page 40: Csdv40

    CSDV Series Direct Vent Gas Stove CSDV40 Replacement parts 586056 CSDV40 parts REpLACEmENT pARTS 58D6056...
  • Page 41 Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 58D6056 qty. CSDV Series Direct Vent Gas Stove CSDV40NV CSDV40pV 58D0368 58D0368 58D0362 58D0362...
  • Page 42: Massachusetts Residents Only

    CSDV Series Direct Vent Gas Stove massachusetts Residents Only — please read and follow these special requirements NOTE REGARDING VENTED pRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
  • Page 43: Warranty

    LIFETImE WARRANTy Covered under this warranty are the stove body, combustion chamber, door frame, gold plating (manufacturing defects only), glass (thermal breakage only), heat exchange system, and burner. This coverage includes parts and reasonable labor during the first five years of ownership and parts only thereafter.
  • Page 44 mHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

Table of Contents