Programming Learn Disable / Learn Enable; Reset Factory Default Settings - COMPX StealthLock SL-100 Instruction Manual

Table of Contents

Advertisement

Programming Learn Disable / Learn Enable

Learn Disable / Learn Enable Mode allows the supervisor to either allow or not allow a
user to program a new user code. In Learn Disable Mode, only the users with knowledge
of the supervisor code can make any programming changes.
There is a 60 second programming time limit to each step. If you time out or make an
error, programming will end and you will need to restart from step 1.
1.
We suggest reading through instructions prior to beginning programming
2.
Press and hold the Receiver Latch learn button until the yellow LED begins a
three blink pattern
3.
Enter the Supervisor pin code and press the Unlock
Then either
a.
Set Learn Disable, enter 3333 and press the Lock
Or
b.
Set Learn Enable, enter 3333 and press the Unlock
4.
If successful the green LED will flash twice on the Receiver Latch
5.
Continue programming or enter 9999 followed by pressing the Lock button to
exit Learn Mode
6.
Test lock function for new mode operation. If Learn Disable has been set, the
Receiver Latch should automatically go to a three blink pattern when the learn
button is pushed and held.
StealthLock
button
button
button
®
, Keyless Invisible Security 15

Reset Factory Default Settings

This feature returns the lock to its original factory settings. This will place the Receiver
Latch into a Non Single Use Mode, Passage Mode, and Learn Enable Mode. It does not
reset the user or supervisor code.
There is a 60 second programming time limit to each step. If you time out or make an
error, programming will end and you will need to restart from step 1.
1.
We suggest reading through instructions prior to beginning programming
2.
Press and hold the Receiver Latch learn button until the yellow LED begins a
three blink pattern
3.
Enter the Supervisor pin code and press the Unlock
4.
Enter 4444 and press the Lock
5.
If successful the green LED will flash twice on the Receiver Latch.
Note that if Single Use mode was exited, the user pin code will default to 0000
6.
Continue programming or enter 9999 followed by pressing the Lock
button to exit Learn Mode
7.
Test lock function to make sure default settings are restored