5-1. How to Enter Test Mode
When main power of DVP-M35 is off, input [TITLE], [CLEAR] then [POWER] from remote commander to enter the test mode. The
following menu appears on the video display. However, this message take some extra time to appear when it enter the test mode for the first
time after the primary power is turned on, because the IF microprocessor calculates check-sums.
Test Mode Menu
0.Syscon Diagnosis
1.Drive Auto Adjustment
2.Drive Manual Operation
3.Mecha Aging
4.Emergency History
5.Other Checks
Exit: POWER Key
In the test mode, all operations are performed from remote commander or from the operation panel using the keys.
To exit the test mode, press the [POWER] key in all modes except the middle of testing.
5-2. System Control Diagnosis
Press the [0] key while the initial menu is being displayed, and enter the diagnosis mode. The following display appears.
Use the adjustment remote commander RMT-D102E (1-475-686-31). (RMT-D101J (1-475-219-11/21) and RMT-D100E/U (1-475-086-31/
51) can also be used.)
Syscon Diagnosis
IF con Ver. 1. 220 (9315)
SYScon Ver. 1. 000 (0000)
Model NO. DPX11????
** Press Remocon Key **
SIRCS:FF KEY:FF
* Note:
When the player enters the diagnosis mode, the RGB output of the Euro AV is turned off.
When a monitor TV is connected using the RGB connection, display of the monitor TV disappears.
Use an NTSC monitor for self diagnosis.
Items 8-9 to 8-13 of the self diagnosis check the. Euro AV output.
SECTION 5
TEST MODE
← Version (check sum) of the IF microprocessor
← Version (check sum) of the SYS microprocessor
(Check sum of the SYS microprocessor is 0000 in the beginning.)
← Indicates the model code.
5-1
DVP-M35