Electronic Pilot Ignition Wiring; Remote Wall Switch - Monessen Hearth Direct Vent Gas Fireplace BDV400 Installation And Operating Instructions Manual

Bdv series direct vent gas fireplace
Hide thumbs Also See for Direct Vent Gas Fireplace BDV400:
Table of Contents

Advertisement

ELECTRICAL INSTALLATION

ELECTRONIC PILOT IGNITION WIRING

Electronic Valve
HI
EV1
EV2
RED #2
WHITE #3
15' Wall Switch Wire
B
LACK
WHITE

REMOTE WALL SWITCH

Position the wall switch. Do not extend beyond the 15 feet of wire.
OPTIONAL DC REMOTE SYSTEMS
These instructions replace the section entitled Hearth Mount in the Millivolt hand held remote instructions supplied with
the remote.
1. Plug in remote connector wire to remote receiver.
2. Connect the wire terminal from the remote receiver. This replaces the 15' wall switch connection to the switch. See
Figure 37.
3. Mount remote control receiver at junction box (for your wall switch).
30
Do not connect 110-120 VAC to the
Remote Wall Switch. The appliance
will malfunction.
Ignition Module
RED #2
GRAY #1
Figure 37 - Remote Wall Switch Wiring Diagram
To Junction Box
Pilot Assembly
Spark
Sense
ON
OFF
YELLOW
RS
GREEN
WHITE
BLACK
BLACK
WHITE
Primary - 120V
Transformer
BLUE
YELLOW
Secondary
24V
YELLOW
54D0700

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bdv300Bdv500Bdv600

Table of Contents