Igniter; Spark And Sensing Electrodes; Overheat Thermostat - Potterton Promax Store 24 Installation And Service Manual

Condensing boiler with integrated hot water storage
Hide thumbs Also See for Promax Store 24:
Table of Contents

Advertisement

Electrode
Leads
Spark
Electrode
Electrode
Leads
Fig. 21
© Baxi Heating UK Ltd 2015
Bracket

Igniter

Igniter Feed
Plug
Sensing
Electrode
4.7
Igniter
1. Remove the air box front cover.
2. Disconnect the igniter feed plug and the
electrode leads, noting their positions.
3. Undo the screw securing the bracket to the
boiler.
4. Remove the igniter and transfer the
bracket to the new component.
5. Reassemble in reverse order.
4.8

Spark and Sensing Electrodes

1. Disconnect the electrode leads, noting
their positions.
2. Remove the retaining screws securing
each of the electrodes to the combustion box
cover and remove the electrodes.
3. Check the condition of the sealing gaskets
and replace if necessary. Reassemble in
reverse order.

4.9 Overheat Thermostat

Re-assemble all parts in reverse order.
1. Perform 4.1 General Access.
2. Disconnect electrical connections and
unscrew the thermostat. Polarity of the
wires is not important.