Ensure that no part of the white outer
Fig. 5c
16
Fig. 5a
chimney duct is visible
Flue Deflector
Fig. 5b
G U I D A N C E N O T E S
Flue Accessories & Fitting Guide
Ø 60/100 Flue Systems
Ø 80/125 Flue Systems
Ø 80/80 Twin Flue Systems
Plume Displacement Kit
(Ø 60/100 Flue Systems)
READ THESE INSTRUCTIONS IN CONJUNCTION WITH THE BOILER
INSTALLATION INSTRUCTIONS BEFORE FITTING THE FLUE
IMPORTANT NOTE: This document
will assist in the correct installation of
the various flue & chimney systems
described within. However, it is the
responsibility of the installer/Gas Safe
registered commissioning engineer to
ensure that the flue & chimney system
is fitted safely and in compliance with
the relevant standards and practices in
force in the country of installation.
Please leave these instructions with the
Installation & Servicing Instructions.
© Baxi Heating UK Ltd 2011
Fig. 5d
Flue Dimensions
The standard horizontal flue kit allows for flue lengths
between 100mm and 685mm from elbow to terminal
(Fig. 5a).
The maximum permissible equivalent flue length is:
10 metres (60/100 system)
Flue Trim
1. The rubber flue trim supplied may be fitted to either
the outside wall or on the inner wall of installation.
Terminal Guard (Fig. 5c)
1. When codes of practice dictate the use of terminal
guards, they can be obtained from most Plumbers% and
Builders% Merchants.
2. There must be a clearance of at least 50mm
between any part of the terminal and the guard.
3. When ordering a terminal guard, quote the
appliance name and model number.
4. The flue terminal guard should be positioned
centrally over the terminal and fixed as illustrated.
Flue Deflector (Fig. 5b)
1. If required a flue deflector is available from your
Potterton stockist.
2. Push the flue deflector over the terminal end. It may
point upwards as shown, or up to 45° either way from
vertical. Secure the deflector to the terminal with
screws provided.
Flue Accessories (Fig. 5d)
1. For full details of Flue Accessories (elbows,
extensions, clamps etc.) refer to the Flue Installation
Guide supplied in the literature pack.
© Baxi Heating UK Ltd 2015