Blot Automatic Thermostat Blower; Fk-12 Manual Blower - Monessen Hearth CDV7 Installation And Operating Instructions Manual

Cdvsc7 series, cdv7 series, direct vent gas fireplace
Table of Contents

Advertisement

CDVSC7 & CDV7 Series Gas Fireplace

BloT auToMaTIC TheRMoSTaT BloweR

Before installing the blower, wire the receptacle into an
electrical circuit. This should be done before framing the
fireplace. Wire with minimum 60° C wire in accordance
with prevailing codes.

FK-12 Manual BloweR

1. This must be done before framing the fireplace. When
installing the FK-1 blower, a wall switch control must
be installed to control the blower.
. The fireplace power supply is wired through the blower
wall switch and then brought to the fireplace junction
box.
3. The jumper clip on the plug receptacle must be re-
moved. Figure 59. Use needlenose pliers to break off
the jumper clip.
Figure 59 -
FK-12 Blower wiring Diagram
40
Receptacle 
WHITE
BLACK
Speed Control 
FP2675
BLOT blower wiring
Plug into switch outlet
FK-12 Blower
opTIonal Fan BloweR SySTeMS
Junction 
Box
WHITE
BLACK
Figure 58 -
BLOT Blower Wiring Diagram
Jumper clip on plug
receptacle must be
removed on power side to
make outlet switchable
Junction Box
FP2676
FK12 wiring
120VAC
BLACK
GREEN
BLACK
Blower
Wall Switch
Red
Black
Black (live)
Green (ground)
White (neutral)
FP676
FP675
69D3011