Check the appliance is electrically safe when you have nished.
10 mm² max
INSTALLATION

Electrical Connection

This appliance must be installed by a suitably quali ed
electrician to comply with the relevant electrical regulations,
and also the local electricity supply company requirements.
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
IF IN DOUBT, PLEASE CONSULT A SUITABLY
WARNING: THE APPLIANCE MUST BE EARTHED.
n
n
Note: The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
The cooker MUST NOT be connected to an ordinary
n
n
domestic power point.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect the
mains cable to the correct terminals for your electrical supply
type (Fig.7-8 and Fig.7-9). Check that the links are correctly
tted and that the terminal screws are tight. Secure the mains
cable using the cable clamp.

Final Checks

Hob Check
Check each cooking zone in turn. Be sure to use pans of the
correct size and material.
Grill Check
Turn on the grill control and check that the grill heats up.
Oven Check
Set the clock as described earlier, and then turn on the ovens.
Check the oven fans start to turn and that the ovens heat up.
26
Breaker with Overload).
QUALIFIED ELECTRICIAN.