Wall
Fig. 19 Side view of final unit location.
Rear Wall Vent Installations -
FP1005
45° Flex Vent Pipe
Side View Vent Termination
Using Kit 7TCD45KT
1/25/00 djt
NOTE: The corner placement dimensions on Page
5, Figure 1 of the manual must be adhered to!
Figures 20 & 21 show general installations. Refer to
instructions below for a detailed description of instal-
lation.
1. Determine where the termination is to be in-
stalled. Locate the center of the hole 29Z\x"
(749 mm) off the floor. (Fig. 20)
NOTE: The location of the termination hole must be
adhered to!
2. Install the firestop as shown on Page 14.
3. Remove the flex vent and extend the flex vent out
to its longest length.
4. Bend the tab on the back of the fireplace up. (Fig.
18)
5. Insert the collar on the flex vent that has the twist
lock embosses on it onto the collar of the fire-
20012253
Secure with Screw
Vent Termination
C L
22"
(559 mm)
Firestop
FP1005a
CDVX Series Direct Vent Gas Fireplace
Termination
C L
to Floor
Flex Section
Appliance
29 "
Collars
(749 mm)
FP1473
Fig. 20 Grasp the vent pipe close to the collar and bend to
45° angle. Do not exceed 45°.
place. Twist the collar to "lock it" onto the fireplace.
Run a screw through the tab and into the collar to
secure the collar onto the fireplace.
6. Bend the flex pipe up 90° as close to the fireplace
as possible. (Fig. 21)
7. Slide the fireplace partially into the corner and,
while holding the vertical portion of the flex vent
pipe, grab the exposed end collar and bend it down
to the height of the opening in the wall.
8. While pushing the unit in place, slide the collar
through the firestop. NOTE: It may be necessary
to trim some material off of the collar. The collar is
made long to accommodate brick finished houses.
(Fig. 23)
9. Secure the collar in place by running a screw
through the tab in the firestop and through the col-
lar.
10. Slide the termination into the collar and secure
with the 4 screws provided. (Fig. 23)
FP1473
corner flex install
4/04 djt
15