VENT INSTALLATION

VENT INSTALLATION

POSITIONING THE FIREPLACE

NOTE: The fireplace must be installed giving full consideration to the clearance and height
requirements identified in this manual.
1. Bend out the six (6) nailing flanges located on the sides and top of the fireplace
2. Slide the firebox into prepared framing or position fireplace in its final position and frame later. Be sure fireplace
is rested on a flat surface.
3. Level the fireplace by checking the top of unit. Shim side-to-side and front-to-back as necessary.
4. Anchor nailing flanges of the fireplace to the side-framing members using 8d nails or other suitable fasteners.

VENTING CONFIGURATION

These models are approved to use listed Monessen Termination Kits and Simpson-Duravent 4' x 6
Components. No other venting systems or components may be used. See PARTS LIST/ILLUSTRATIONS section
for a list of approved vent components.
Any common venting of this gas appliance with other gas appliances is not allowed.
Do not connect this appliance to a chimney flue servicing a separate solid fuel-
burning appliance.
Dim
Min
V
6 feet
12
Max
40 feet
Figure 8 - Venting Vertical Straight Up with No Elbow
/
5
8
NOTE: Two offset 45° elbows
are recommended for vertical
runs of 15 feet or more to
improve flame appearance.
" Direct Vent Pipe